Skip to content
QuickMIC®

The Right Antibiotic. For the Right Patient. Within the Same Shift.

Ultra-rapid antimicrobial susceptibility testing that delivers precise MIC values directly from positive blood cultures. In 2 to 4 hours1.

Speed. Precision. Clinical Confidence.
Built to Support Time-Critical Sepsis Management.

Traditional AST forces your team to wait overnight for results. QuickMIC closes that gap and puts your lab at the center of clinical decision-making.

Report results the same shift

MIC values and SIR categories in 2 to 4 hours. Your clinical team gets answers while the patient is still under active care.

Results you can stand behind

Continuous MIC values with low variability. The precision to confidently guide antibiotic selection.

From empiric to targeted, day one

Enable the clinical team to move from broad-spectrum to targeted therapy faster. Better for the patient. Better for AMR.

Easy to Add.
Fast to Get Going.

QuickMIC fits alongside your existing AST. No infrastructure changes, no lengthy validation. Typical onboarding is two weeks.

~2 wks Typical onboarding
4.7/5 Customer rating
100+ Installations

The QuickMIC System.
Built Around Your Workflow.

QuickMIC Instrument

QuickMIC® Instrument provides the conditions for growth and detection of bacterial microcolonies in the QuickMIC cassette, and for creating and maintaining the antibiotic gradient in the cassette chambers. The instrument provides image analysis data to the QuickMIC® Analyst software for determination of MIC values.

QuickMIC GN

Validated for E. coli, K. pneumoniae complex, K. oxytoca, K. aerogenes and K. variicola, P. aeruginosa, A. baumannii-calcoaceticus complex, Enterobacter cloacae complex, P. mirabilis, P. vulgaris, C. koseri, C. freundii and S. marcescens.

Download drug bug combination

  • Amikacin
  • Cefepime
  • Ciprofloxacin
  • Colistin
  • Cefotaxime
  • Ceftazidime/avibactam
  • Ceftazidime
  • Gentamicin
  • Meropenem
  • Piperacillin/tazobactam
  • Tigecycline
  • Tobramycin
QuickMIC GN02

Validated for E. coli, K. pneumoniae complex, K. oxytoca, K. aerogenes and K. variicola, P. aeruginosa, A. baumannii-calcoaceticus complex, Enterobacter cloacae complex, P. mirabilis, P. vulgaris, C. koseri, C. freundii and S. marcescens.

Download drug bug combination

  • Amikacin
  • Aztreonam/avibactam
  • Cefepime
  • Cefiderocol
  • Ceftazidime
  • Ceftazidime/avibactam
  • Ceftolozane/tazobactam
  • Ciprofloxacin
  • Colistin
  • Meropenem
  • Meropenem/vaborbactam
  • Piperacillin/tazobactam

Learn more about QuickMIC GN02

QuickMIC Analyst

QuickMIC® Analyst software controls instrument operation and determines, interprets and presents MIC values based on image analysis data provided by the instrument.

The software analyses the growth patterns of each microcolony along a linear antibiotic gradient to determine precise MIC values. SIR interpretation is done automatically in the software using EUCAST breakpoint tables and Expert rules.

Real-Time

Imaging throughout the run

Per-Antibiotic

Results reported as they’re ready

Drug susceptibility

Actual response regardless of the underlying resistance mechanism

Watch the Biology Unfold.

QuickMIC monitors bacterial growth through real-time imaging. The system captures microcolony formation across the full antibiotic gradient, tracking how organisms respond at every concentration point.

Growth rates are calculated continuously as data comes in. MIC values are determined per antibiotic and reported independently as soon as they are ready. No need to wait for the full panel to complete.

  • Live imaging
  • Per-antibiotic reporting
  • Phenotypic AST

Simple to Run.
Easy to Report.

From positive blood culture to reportable MIC. Here’s what your team actually does.

1. Prepare

Load the cassette with growth medium and gel-embedded sample.

2. Insert

Place the cassette into an available instrument.

3. Start run

Click Start Run. The system handles the rest automatically.

4. Report

MIC results arrive per antibiotic as they become available. Ready to report together with SIR categorisation.

How QuickMIC Finds the Precise MIC

The MIC is the lowest antibiotic concentration that 
stops bacterial growth. The question is how precisely 
you can find it.

Traditional AST 2-fold Dilution

Tests a few fixed concentrations. If the actual MIC falls between two steps, it gets rounded. One dilution off can shift S to I. Each well tests bacteria at one fixed concentration. Growth or no growth. Growth at 4, no growth at 8. The actual MIC (6) was never tested. Reported as MIC = 8 µg/mL.

QuickMIC® Continuous Gradient in Cassette

Tests every concentration at once in a continuous antibiotic concentration gradient for each antibiotic inside the cassette. The MIC is where growth stops. No gaps, no rounding. You see exactly where bacteria stop growing inside the channel. The system reports MIC = 3 µg/mL. No rounding, no ambiguity near breakpoints.

Technical Specifications

Time to result 2 to 4 hours from positive blood culture
Sample type Positive blood cultures (Gram-negative)
Output Quantitative MIC values (µg/mL)
Capacity 1 sample/run per instrument, up to 12 instruments stacked
Dimensions 230 x 415 x 210 mm (WxDxH)
Connectivity Bi-directional LIS integration

See How QuickMIC Works in Your Lab.
Talk to Our Team.

The Science
Behind QuickMIC

QuickMIC is supported by a growing body of peer-reviewed research. Clinical studies conducted across European and U.S. laboratories have evaluated the speed and precision of the system, comparing its performance against established AST methods in routine clinical settings.

7+ peer-reviewed studies
3+ multicenter studies
88% same-shift reporting

References

  1. A multicenter evaluation of a novel microfluidic rapid AST assay for Gram-negative bloodstream infections, Berinson et.al., (2024) – Journal of Clinical Microbiology